Skip to textbook content
Doctor’s PassportTextbook
QuestionsFlashcardsBriefsDashboardAccount
TopicsAll topics

Loading topic navigation…

Textbook navigation
TopicsAll topics

Loading topic navigation…

Educational draft · awaiting clinical reviewUse Rapid for revision, not patient-care decisions. Check current national and local guidance and the BNF or BNFC before acting.

Endoanal ultrasound and anorectal physiology

Colorectal surgery · UK scope · Sources checked 8 Sept 2026 · Clinical review pending

RapidFull

Synopsis

Select complementary anorectal tests for a defined anatomical or functional question, explain the procedure and interpret results without mistaking one measurement for a complete diagnosis.

  • Endoanal ultrasound shows the anal sphincter anatomy and is useful when planning a possible sphincter repair. A visible defect does not by itself explain symptom severity or predict which continence treatment will work.
  • Anorectal physiology examines pressures, sensation and aspects of coordination. Balloon expulsion tests evacuation performance; dynamic imaging examines evacuation and associated anatomy. Choose according to the decision that remains unresolved.
  • Explain the anal probe or catheter, the requested manoeuvres and how the patient can raise concerns before obtaining consent. If the procedure causes pain, stop and assess the problem instead of continuing to obtain a complete trace.
  • An abnormal balloon expulsion result supports impaired evacuation, but does not identify every structural or functional cause. Relate it to the symptoms, other test findings and how the test was performed.
  • Normal sphincter imaging does not exclude all causes of leakage. Mixed leakage and obstructed defaecation may justify complementary dynamic assessment rather than an automatic repeat of the same anatomical test.
  • Measure colonic transit when it answers a colonic question, and before considering surgery for constipation. Rectosigmoid marker accumulation alone is not a diagnosis of pelvic-floor dyssynergia.

Key red flags

Pain should stop the examination

Tell the patient to report pain during catheter or probe testing. Stop the examination if pain occurs, assess the problem and discuss what can safely follow before attempting to continue. Preserving consent and comfort takes priority over completing every measurement; record when the examination is limited or discontinued.

Investigation priorities

01
Define the indication and prepare the patientFirst step

Review symptoms, relevant operations and prior results; identify the management question. Explain catheter or probe insertion and the requested tasks, obtain consent and make clear that pain should be reported so the test can be stopped and reassessed.

Management branches

Worked case: an anatomical decisionMap the sphincter before a possible repair

A 55-year-old with persistent incontinence after appropriate conservative care is considering a specialist repair discussion. The surgeon needs to establish whether there is a relevant anal sphincter defect following a previous obstetric injury.

  1. The clinical history and examination establish the symptom burden and the proposed decision. The request asks for sphincter anatomy relevant to repair, rather than a generic test of bowel function. Endoanal ultrasound is selected because it directly addresses that anatomical question.
  2. The patient receives an explanation of the probe examination, gives consent and knows to report pain so testing can stop. The report identifies an external sphincter defect and describes the anatomical findings for the specialist team.
  3. The team explains that this result supports a repair-planning discussion but does not quantify every cause of leakage or guarantee benefit from surgery. Stool pattern, function, patient goals and the expected balance of benefit and burden remain relevant.
  4. The patient receives the result and participates in the next decision. The documented endpoint is informed treatment planning based on the anatomy, rather than an unsupported claim that finding the defect establishes the only cause or mandates an operation.
Worked case: stable mixed symptomsAdd a complementary view when ultrasound leaves a question
Open full textbook →Answer 2 questions
Sources and review status4 sources · checked 8 Sept 2026 · clinical review pending+
Sources

Sources and review status

National guidance is shown before implementation-dependent detail. Apply principles in context and verify current guidance when a decision affects care. Source check completed 8 Sept 2026; clinical approval remains outstanding.

  • ASCRS 2023 faecal-incontinence guideline: physiology and endoanal ultrasound
  • ASCRS 2024 constipation guideline: outlet and transit assessment
  • Ashford and St Peter’s NHS: anorectal physiology studies, September 2025
  • IAPWG original consensus: advances in the evaluation of anorectal function, 2018

Editorial contact: Doctor’s Passport editorial team. Source-check date is separate from clinical approval. Report a content problem · Content changes

Authoring stateRapid draftClinical stateAwaiting reviewJurisdictionUnited Kingdom

A 63-year-old has leakage as well as prolonged, incomplete evacuation. Endoanal ultrasound shows an intact sphincter complex, but the symptoms remain troublesome after initial measures.

  1. The clinician explains that the scan answered an anatomical sphincter question. It did not show the full process of defaecation, and the patient’s continuing symptoms do not conflict with an intact sphincter image.
  2. The specialist requests dynamic evacuation assessment to investigate the combination of obstructed defaecation and leakage. The request records the residual symptoms and the completed ultrasound result, making the reason for a complementary test explicit.
  3. The study demonstrates internal intussusception during evacuation in this illustrative case. The team correlates the finding with the history and other functional information before deciding how much it contributes; its presence does not automatically determine an operation.
  4. The patient and team agree the next management discussion from the combined evidence, with a plan to review both emptying and leakage outcomes. The assessment has advanced by answering a different question, rather than repeating an already adequate sphincter scan.