Synopsis
Identify and localise suspected button-battery ingestion rapidly, coordinate safe removal and recognise delayed injury even after the battery has passed or been extracted.
- Localise suspected ingestion urgently with appropriate AP and lateral radiographs covering neck, chest and abdomen; look for a double rim and lateral step-off, but an indistinct sign does not exclude a battery.
- Remove an oesophageal battery immediately without waiting for fasting or symptoms. Honey, when eligible, is temporary mitigation and must not delay transfer or removal.
- Honey: child older than one year, known ingestion less than twelve hours ago, stable and able to swallow, with no perforation, mediastinitis, sepsis or honey-allergy concern; give 10 mL orally every ten minutes, maximum six doses.
- A battery beyond the oesophagus can still require urgent intervention or investigation of earlier oesophageal injury; symptoms, magnets, delay and anatomy matter.
- The 2021 ESPGHAN algorithm and July 2026 Endoscopy SIG opinion have different gastric-risk details. The latter is not endorsed ESPGHAN policy and should be read alongside the position paper.
- Admit and monitor a child with mucosal injury after removal, assess complications and establish a safe feeding and follow-up plan.
- Delayed bleeding, new dysphagia or respiratory symptoms after apparent recovery requires urgent reassessment; removal does not instantly stop all tissue injury.