Educational draft · awaiting clinical reviewUse Rapid for revision, not patient-care decisions. Check current national and local guidance and the BNF or BNFC before acting.

Congenital hearing loss and newborn screening

Ear, nose and throat · UK scope · Sources checked 8 Sept 2026 · Clinical review pending

RapidFull
!
Some babies need diagnostic audiology directly

Confirmed congenital CMV, neonatal bacterial meningitis or meningococcal septicaemia, microtia or canal atresia, and a programmable ventriculoperitoneal shunt require direct diagnostic referral under England’s NHSP pathway. Screening should not delay the indicated assessment.

Action: The medical team should communicate the reason to audiology and arrange the appropriate early assessment, with an expedited paediatric and audiological plan for confirmed congenital CMV.

Synopsis

Interpret newborn hearing results within the correct pathway, obtain timely diagnostic assessment and support communication while defining the type and cause of hearing loss.

  • A newborn screen identifies babies needing further assessment; a clear response does not exclude mild, progressive or later-onset hearing loss.
  • In England, use the well-baby or NICU protocol correctly. AABR no clear response in either ear requires audiology referral, and confirmed high-risk exclusions go directly to diagnostic assessment.
  • Act on later parental concern regardless of screening history. Explain results and provide communication support promptly rather than waiting for speech delay to become established.
  • The NICU pathway uses both AOAE and AABR in both ears; bilateral AOAE no clear response with bilateral AABR clear response requires targeted follow-up.
  • Diagnostic assessment distinguishes conductive, sensorineural, mixed and auditory-neuropathy patterns using appropriate tests; automated screening is not an audiogram.
  • When permanent loss is confirmed, discuss early support and amplification with the family, and arrange investigation of cause without postponing communication support.
  • Secure hearing-device battery compartments and keep loose button batteries inaccessible; a missing battery or possible ingestion requires urgent action.

Key red flags

Parental or professional concern about responses to sound or vocal development needs audiological assessment even after a clear newborn screen.

A no-clear-response AABR result in either ear requires diagnostic referral; repeating screening to obtain a pass can delay diagnosis.

Confirmed congenital CMV requires a rapid agreed assessment because treatment decisions can be time sensitive.

Missed diagnostic appointments after a positive screen require active follow-up, coordinated support and consideration of safeguarding where appropriate.

Investigation priorities

01
Diagnostic frequency-specific ABRFirst step

Estimate ear-specific hearing thresholds and characterise the loss.

Management branches

Worked caseA screen referral becomes an early support and amplification plan

A term infant has no clear response in either ear at the final AABR stage of the well-baby screen, completed at two weeks of age.

  1. The screener explained that the result required diagnostic testing rather than proving permanent deafness, made the audiology referral and confirmed an appointment within the required interval. The parent received written information, contact details and preparation advice for a settled or sleeping infant.
  2. At five weeks, specialist testing measured raised air- and bone-conduction thresholds in both ears, with middle-ear findings that did not explain the loss. A prompt repeat assessment completed by seven weeks confirmed bilateral permanent sensorineural impairment, and the clinician explained the degree and remaining aetiological questions to the family.
  3. With consent, the team referred to early sensory support within one working day and arranged paediatric assessment. Appropriate hearing-aid fitting was offered and completed within four weeks of confirmation, alongside practical support for communication and safe handling of the devices and batteries.
  4. At the next audiology review, fitting checks and observed responses supported useful access to sound with the aids, and the family demonstrated safe device use. The team documented an ongoing hearing and developmental follow-up plan; the benefit observed did not remove the need to monitor growth, hearing change and communication progress.
Open full textbook →Answer 2 questions
Sources and review status5 sources · checked 8 Sept 2026 · clinical review pending+
Sources

Sources and review status

National guidance is shown before implementation-dependent detail. Apply principles in context and verify current guidance when a decision affects care. Source check completed 8 Sept 2026; clinical approval remains outstanding.

  • England NHSP patient journey updated February 2026
  • England NHSP surveillance and audiological referral updated February 2026
  • BSA early audiological assessment and management guidance
  • NICE TA566 cochlear implantation recommendations
  • England newborn hearing screening pathway requirements

Editorial contact: Doctor’s Passport editorial team. Source-check date is separate from clinical approval. Report a content problem · Content changes

Authoring stateRapid draftClinical stateAwaiting reviewJurisdictionUnited Kingdom