Measure intra-abdominal pressure correctly in at-risk critically ill patients, diagnose organ dysfunction attributable to sustained hypertension and escalate medical decompression and surgery before irreversible failure.
Intra-abdominal pressure affects every organ sharing the closed abdominal cavity. As volume rises or compliance falls, the diaphragm is displaced upward, venous return is impaired and renal and splanchnic vessels are compressed. Ventilation requires higher pressure, cardiac output falls despite a high measured central venous pressure, kidney filtration declines and bowel perfusion worsens. The resulting capillary leak and fluid resuscitation can create a self-amplifying cycle.
The WSACS definition separates intra-abdominal hypertension from abdominal compartment syndrome. Hypertension is a measured pressure abnormality; syndrome requires new organ dysfunction attributable to sustained pressure above 20 mmHg. Bladder pressure is the reference intermittent method when technique is standardised. Treatment progresses in parallel: evacuate intraluminal contents, drain fluid or blood, improve wall compliance, correct excessive fluid balance and support perfusion. Decompressive laparotomy is needed when non-operative measures cannot reverse pressure-driven organ failure.
Ileus, obstruction and gastric or colonic dilatation increase gas and fluid inside bowel; gastric and rectal decompression target this compartment.
Haemorrhage, ascites, pus and visceral oedema occupy fixed cavity capacity; image-guided drainage helps only when the material is accessible and drainable.
Burn eschar, tight dressings or closure, pain-related contraction and some body positions reduce available expansion and magnify the pressure effect of a given volume.
Sepsis, pancreatitis, burns and haemorrhage resuscitation promote bowel and wall oedema; after adequate rescue, continuing positive balance can worsen IAH.
Upward displacement reduces functional lung volume and compliance, increasing peak and plateau airway pressures and worsening basal atelectasis and hypoxaemia.
Caval compression and raised intrathoracic pressure reduce effective preload while venous congestion can make central filling-pressure values appear deceptively high.
Raised renal interstitial and venous pressure plus reduced perfusion gradient lower glomerular filtration, so oliguria may worsen when more fluid adds oedema.
Reduced abdominal perfusion impairs gut mucosa and microcirculation, increasing permeability, bowel oedema and the pressure-volume feedback cycle.
Rising peak and plateau airway pressures, reduced compliance, basal collapse and hypoxaemia appear as the diaphragm is forced cephalad.
Oliguria and creatinine rise reflect renal-vein, parenchymal and arterial compression and may precede refractory shock.
Reduced venous return and increased afterload lower cardiac output while intrathoracic pressure can make filling-pressure measurements misleadingly high.
Tense distension after haemorrhage, pancreatitis, burns, sepsis, packing or high-volume resuscitation identifies a patient who needs pressure measurement.
A tense abdomen with IAP below the syndrome threshold or without new attributable organ dysfunction is distension or IAH, not abdominal compartment syndrome.
Ventricular failure can cause low output, renal injury and raised venous pressure; echocardiography and pressure response separate it from a dominant abdominal mechanism.
Tube obstruction, bronchospasm, pneumothorax and lung oedema raise airway pressure independently, so respiratory troubleshooting accompanies IAP measurement.
Sepsis, nephrotoxins or tubular injury can cause oliguria despite a modest IAP; urinalysis, renal trend and full haemodynamics prevent causal over-attribution.
Progressive loss of compliance and lung volume can make ventilation and oxygenation refractory; decompression response is assessed through airway pressures and gas exchange.
Sustained renal venous and parenchymal compression can progress from oliguria to metabolic or volume indications for renal replacement therapy.
Low splanchnic perfusion disrupts mucosal barrier and may progress to necrosis or leak, adding contamination and further capillary leak.
Decompressive laparotomy relieves pressure but creates fluid and heat loss, fascial retraction, infection and enteric-fistula risk that temporary closure must address.
Obesity, muscle tone and dressings make palpation unreliable; bladder pressure provides a reproducible measurement linked to organ change.
Raised thoracic pressure may elevate central venous pressure even while venous return and cardiac output are impaired.
Renal dysfunction reflects direct parenchymal and venous pressure as well as reduced arterial perfusion, so more fluid can worsen the cause.
Decompression can be life-saving but starts open-abdomen risks; temporary closure and early fascial strategy are part of the initial operation.
Diagnosing ACS from a tense abdomen without measuring pressure confuses risk with syndrome.
Calling every IAP above 12 mmHg ACS ignores the requirement for pressure above 20 mmHg and new organ dysfunction.
Instilling a large bladder volume artificially raises the reading and breaks standardisation.
Giving repeated crystalloid for oliguria without considering pressure can amplify bowel oedema and organ compression.
Your practice draft is saved in this browser.
A patient has sustained intra-abdominal pressure of 23 mmHg with new oliguria and rising ventilator pressures. Which classification applies?
National guidance is shown before implementation-dependent detail. Apply principles in context and verify current guidance when a decision affects care. Source check completed 7 Sept 2026; clinical approval remains outstanding.
Editorial contact: Doctor’s Passport editorial team. Source-check date is separate from clinical approval. Report a content problem · Content changes