Principles and purpose
Review why each drain or line is present, maintain its intended closed system, recognise complications and arrange safe device-specific removal or escalation.
A drain or catheter changes normal anatomy to provide a particular function: evacuating a wound space, draining urine, delivering treatment or obtaining vascular access. Safe care starts with that purpose. The presence of tubing does not prove it is functioning, and an apparently tidy dressing does not exclude a complication beneath it. At each review establish why the device remains necessary, what normal performance means for this patient and who can authorise changes. A drain used after abdominal surgery may carry information about an internal leak, while a small plastic-surgery suction drain may be tracking local wound fluid. Interpreting both as simply “output in millilitres” loses the clinical context.