Educational draft · awaiting clinical reviewUse Rapid for revision, not patient-care decisions. Check current national and local guidance and the BNF or BNFC before acting.

Drain, line and catheter care

General surgery · UK scope · Sources checked 8 Sept 2026 · Clinical review pending

RapidFull
!
Escalate

Assess the patient immediately if a device problem accompanies breathlessness, collapse, severe bleeding, rapidly worsening pain, fever with systemic illness or suspected obstruction. Stop using an unsafe vascular line and obtain urgent clinical help.

Synopsis

Review why each drain or line is present, maintain its intended closed system, recognise complications and arrange safe device-specific removal or escalation.

  • Identify the exact device, site, indication, insertion date and authorised care plan before touching it. A wound drain, chest drain, central line and urinary catheter are not managed interchangeably.
  • Check the patient first, then trace the system from skin to collection bag or connection. Look for displacement, kinks, loss of suction, leaks, inflammation and changes in output.
  • Preserve asepsis and the intended closed system; do not force a blocked line, reinsert a dislodged drain or apply generic clamping instructions to an unfamiliar device.
  • For an adult urinary catheter, maintain unobstructed drainage with the bag below bladder level and off the floor; collect indicated urine samples aseptically from the sampling port, not the bag.
  • Record wound-drain output with a time interval, volume and character for each drain separately. Removal depends on the operation, output and responsible team’s decision.
  • Check daily whether the device is still needed and arrange removal by a competent practitioner using the correct procedure, with explicit follow-up and deterioration instructions.

Key red flags

New systemic illness, rigors or spreading insertion-site inflammation may represent device-associated infection and require urgent assessment.

Sudden bloody drain output, falling blood pressure or increasing abdominal pain is not a routine bottle-management problem.

A broken central line, a displaced device, severe arm or neck swelling, or new breathlessness requires prompt device-specific escalation.

A catheter that has stopped draining with a painful distended bladder, worsening renal function or systemic illness needs urgent assessment rather than observation alone.

Possible device-associated infection

Inspect for spreading redness, tenderness, discharge or tracking inflammation and ask about fever, rigors and feeling unwell. Assess observations and the whole patient. A line or drain may be a source, but other postoperative causes remain possible; the severity of illness determines the urgency, not the size of the device.

Output that changes the surgical assessment

A sudden rise in fresh blood, an unexpected change in abdominal drain contents or cessation accompanied by pain and swelling needs review. Record what changed and over which interval. A low volume may indicate recovery, a blocked system or fluid collecting elsewhere, so it is not by itself permission to remove the drain.

Vascular line malfunction

Pain or swelling during administration, new leakage, resistance or inability to aspirate warrants stopping use and assessment under the device protocol. With a tunnelled line that cracks, close its designed clamp on the patient side of the break if possible and seek urgent specialist advice. New breathlessness or collapse requires emergency assessment.

Reasoning priorities

01
First-line patient and device review

Determine whether the priority is resuscitation, correction of a simple external problem or specialist review.

Check observations, symptoms and relevant examination, then the documented device type, indication, insertion date, fixation and visible circuit. A reassuring bottle volume does not outweigh a deteriorating patient.

02
Preferred timed output and fluid-balance review

Interpret performance against the clinical course rather than one isolated number.

Measure each drain separately and describe colour and consistency as well as volume and elapsed time. Relate urinary output to intake, renal function and bladder symptoms. An apparent change may reflect a changed measurement interval, but this must be confirmed rather than assumed.

Worked reasoning

Worked caseA suction drain loses its expected function

A constructed adult case: a patient at home after a plastic-surgery procedure notices leakage around a suction wound drain and a bottle that no longer appears to hold its prescribed vacuum.

  1. The telephone clinician first asks about bleeding, fever, worsening pain, swelling, breathlessness and general condition. The patient is well and reports a small clear leak, with no rapidly enlarging swelling. This assessment supports prompt team advice rather than assuming an emergency or reassuring without questions.
  2. The patient identifies the supplied wound-drain system and confirms that the tube is still secured. They are told to leave it in position, protect leaking fluid with an appropriate absorbent dressing and contact the surgical service. They are not asked to improvise a connection, flush the drain or push it further into the wound.
  3. At the arranged clinic assessment, the team confirms loss of suction, inspects the wound and reviews recorded output. There is no clinical evidence of a collection or infection. A trained practitioner replaces the collection system according to that specific drain’s instructions, and the prescribed vacuum is restored.
  4. The patient demonstrates how they will secure the bottle and record the next timed output. The team documents a further review and removal decision. At that review the wound remains comfortable and the recorded trend supports removal under the surgeon’s plan; low output was interpreted with examination and procedure context.
Open full textbook →Answer 2 questions
Sources and review status9 sources · checked 8 Sept 2026 · clinical review pending+
Sources

Sources and review status

National guidance is shown before implementation-dependent detail. Apply principles in context and verify current guidance when a decision affects care. Source check completed 8 Sept 2026; clinical approval remains outstanding.

  • NICE CG139: Healthcare-associated infections, recommendations
  • EAUN 2024: Indwelling catheterisation in adults, nursing management
  • EAUN 2024: Indwelling catheterisation in adults, urinalysis
  • NICE NG113: Catheter-associated urinary tract infection
  • WHO 2024: Prevention of bloodstream infections associated with intravascular catheters, recommendations
  • University Hospitals Sussex: Going home with a wound drain
  • University Hospitals Sussex: Your abdominal drain passport
  • Cambridge University Hospitals: Care of your tunnelled central line
  • RCoA GPAS: Anaesthesia services for day surgery 2025

Editorial contact: Doctor’s Passport editorial team. Source-check date is separate from clinical approval. Report a content problem ·

Routine careMaintain a wound drain and preserve useful information

An adult has a postoperative wound or abdominal drain with an established surgical care plan.

  1. Confirm the drain’s location, intended mechanism and output expectations. Secure the tubing and container to avoid traction, keep the relevant collection system in its prescribed position and inspect fixation and dressing. Check whether a closed-suction indicator shows the intended vacuum; different products signal this differently.
  2. Perform hand hygiene before and after handling. Change a wet or soiled dressing using the prescribed aseptic method, and avoid unnecessary disconnection. Only trained staff or specifically taught patients should change the collection system. Do not strip, milk, clamp or flush tubing simply because a different drain once required that action.
  3. Record each drain on its own chart with time, measured volume, appearance and any loss of suction or leakage. Escalate unexpected blood, a major increase, sudden cessation with symptoms, infection signs or displacement. If a wound drain falls out, cover the site and contact the responsible service; do not reinsert it.
  4. Review continued need with the operating team. The removal decision reflects the operation, examination and output trend, without a universal volume threshold. A competent practitioner follows the specific sequence, including any required release of suction and identification of its securing stitch, then checks the removed device and documents the result.
Device-specific careManage urinary and vascular access without crossing protocols

The daily review includes an indwelling urinary catheter, peripheral cannula or central venous access device.

  1. For a urinary catheter, keep the drainage circuit closed, the bag below the bladder and off the floor, and tubing free of dependent obstruction or traction. Review hydration and bladder symptoms in clinical context. Routine disconnection, antiseptic bladder washouts and treatment of an isolated positive culture are not substitutes for appropriate assessment.
  2. If symptomatic catheter-associated UTI is suspected, obtain a suitable sample and assess severity. NICE advises considering removal or change when the catheter has been in place for more than seven days, while making clear that the change must not delay antibiotic treatment. An essential catheter is changed through the trained service; altered anatomy or a suprapubic tract needs the appropriate expertise.
  3. For peripheral or central vascular access, inspect the site and dressing, maintain aseptic access to connectors and review whether ongoing therapy still requires the device. Stop administration when there is pain, swelling, leakage, resistance or concern about position. Follow the relevant complication pathway and do not force a flush to prove patency.
Content changes
Authoring stateRapid draftClinical stateAwaiting reviewJurisdictionUnited Kingdom
For a cracked tunnelled central line, prevent further use, close the designed clamp between the patient and the damaged segment where possible, cover the crack with a dressing and arrange urgent vascular-access assessment. If the device has come out, lie down immediately, apply pressure for bleeding and obtain urgent help. Repair, exchange and removal are specialist decisions; a cuffed tunnelled line is not removed like a peripheral cannula.