Synopsis
Review why each drain or line is present, maintain its intended closed system, recognise complications and arrange safe device-specific removal or escalation.
- Identify the exact device, site, indication, insertion date and authorised care plan before touching it. A wound drain, chest drain, central line and urinary catheter are not managed interchangeably.
- Check the patient first, then trace the system from skin to collection bag or connection. Look for displacement, kinks, loss of suction, leaks, inflammation and changes in output.
- Preserve asepsis and the intended closed system; do not force a blocked line, reinsert a dislodged drain or apply generic clamping instructions to an unfamiliar device.
- For an adult urinary catheter, maintain unobstructed drainage with the bag below bladder level and off the floor; collect indicated urine samples aseptically from the sampling port, not the bag.
- Record wound-drain output with a time interval, volume and character for each drain separately. Removal depends on the operation, output and responsible team’s decision.
- Check daily whether the device is still needed and arrange removal by a competent practitioner using the correct procedure, with explicit follow-up and deterioration instructions.